Overfill Protection& Grounding System for oil loading process
- Price
- US $770-855
- Model
- SLA-S-IIC
- MOQ
- 5 piece
Item specifics
- Clamp length: 5m
- 5m
- Sensor length
- 6m
- Alarm
- Visible and Audible Alarms
Review
Description
1. Introduction
The "Overfill Protection and Grounding Systems" are designed for top loading of road tankers, rail cars, etc. ln the event of an overfill condition, the overfill sensors will send a signal through the output relay to the terminal automated loading system to shut down the loading operation. The systems provide overfill protection as well as grounding verification.
2. Advantages
1. Audible and visible alarms.
2. Upon the loss of a ground connection or an overfill condition, the Overflow and grounding protector will send a signal to immediately shut off the loading operation.
3. LED display provides the resistance value of the ground connection.
4.The overfill sensor has a continuous self-check and alert feature to ensure the system is working properly.
3. Specifications
Input Power: 220VAC±10%
Input current: <35mA
Monitoring Set Point: 10 ohms
Output Signal: 30V DC ,10A /250V AC ,10A
Ingress Protection: IP65
Spiral Cable: Extendable to 5.3 m (17.4ft.)
Operation Temperature: -40℃ to +60℃
(-40℉ to +140℉)
Sensor Cable Length: 6m(20ft.)
Alarm Volume: >90dB
4. Installation Diagram & Dimensions
5. Package
Dimensions:40*35*40 cm
Gross Weight: 6.0 kgs
Delivery time: 2 days after payment
Delivery: by sea or courier such as FedEx, DHL, TNT, UPS
6. Company Information